ERCOT·WATCH Search ercot.com  ⌕
LPGRR #32 · Revision Request

LPGRR032  Profile Decision Tree Changes for Advanced Meters

Approved sponsor Ernie Podraza on behalf of the Profiling Working Group (PWG) posted 2008-10-10 ercot.com
ReasonTo allow for 15-minute settlement of ESI IDs with Advanced Meters.
Created2008-11-21
Approved2009-03-17
Sections Affected
Appendix D: Profile Decision Tree
Summary
This change specifies a meter data type assignment of ‘IDR’ and a Profile Segment assignment other than ‘IDRRQ’ for Electric Service Identifiers (ESI IDs) with Advanced Meters. For ESI IDs that have a meter data type of IDR (includes Advanced Meters and IDRs), the default weather sensitivity code assignment is changed to ‘weather sensitive’. For simplicity, this change treats all ESI IDs that have a meter data type of ‘IDR’ in the same manner. The default weather sensitivity code assignment is not retroactive.
Timeline